Bengaluru
08045135424
+919108006731

level transmitter

68179d65be22ee500d53ff54 Card 2

product image
Level Transmitter

Radar Level Transmitter FILPRO offers professional Radar Level Transmitter. ​ Our radar level transmitter uses radar to continuously measure non-contact liquid level, the sensor sends microwave signals to the medium from above. ​ The surface of the medium reflects the signal back to the sensor. ​ The radar sensor uses the received microwave signal to determine the distance to the product surface and calculate the height from it. ​ Radar level transducer is an excellent substitute for differential pressure instruments, magnetostrictive, radio frequency admittance, and Ultrasonic level transmitter. ​ The radar level transmitter is not affected by vacuum, dust, temperature, pressure changes, steam and falling gases. ​ An ISO 9001:2008 Company ​ FRLT-80S ​ Application: Liquid Measurement ​ Measuring Range: 0~10m ​ Antenna Type: Lens/PTFE ​ Mounting Thread: Thread G1.5 Beam Angle: 8° ​ Response Time: <0.6s (Due To Parameter Setting) ​ Medium Temperature: (-40 ~ 120) °C ​ DK Value Of Medium: 1.5 ​ Process Pressure: (-0.1 -0.3) MPa ​ Accuracy: <2mm ​ Signal Output: (4-20) mA HART ​ Working Frequency: (76 -81) GHz ​ Explosion Proof Grade: Ex d[iaGa] IIC T6 Gb ​ Instrument Type Standard Explosion-Proof ​ Housing/Protection Grade ​ Aluminum Alloy/IP68 ​ Aluminum Alloy Dual Chamber/IP67 ​ Special Terms ​ Antenna Type ​ Lens/PTFE G1.5 ​ Anti-Corrosive ​ Process Connection Thread G1.5 ​ Special Terms ​ Electronic Unit ​ 2 Wires (4 ~ 20) mA 24VDC/HART ​ 4 Wires (4-20) mA 220V AC ​ Special terms ​ Cable Inlet ​ M20*1.5 NPT1/2 Material Type ​ Liquid Special Terms ​ FRLT-63 ​ Application: Solid Particles, Solid Powder, All kinds Of Dust Environment ​ Measuring Range: 0-70m ​ Connection Process: Flange ​ Medium Temperature: (-40-350)°C ​ Process Pressure: (-0.1-2) MPa Directional ​ Accuracy: ±15mm Signal Output: (4-20)mA HART/RS485 MODBUS ​ Explosion-Proof Grade: Ex ia IIC T1-T6 Ga/Ex d IIC T6 Gb ​ Protection Grade: IP68 ​ Frequency Range: 26GHz ​ Instrument Type ​ Standard Flameproof Intrinsically Safe Explosion-Proof Type ​ Housing/Protection Grade ​ Die-Casting Aluminium With Epoxy Coating/IP68 ​ Die-Casting Aluminium With Epoxy Coating Dual Chamber/IP67 ​ Material ​ Stainless Steel 316L ​ Special Custom ​ Sensor Type ​ Directional Purge Type ​ Universal Purge Type ​ Process Connection 1½" NPT Thread (Directional) Flange DN80 ​ Flange DN100 ​ Flange DN200 ​ Special Custom ​ Antenna Type ​ Horn Antenna Ø98 ​ Horn Antenna Ø96 Longer ​ Special Custom ​ Seal/Process Temperature ​ Viton/(-40 -150)°C ​ Kalre/(-40 -350)°C (With Heat Sink) ​ Electronic Unit ​ (4 -20)mA 24V DC/HART Two-Wire ​ (4 -20)mA 220V AC/Four-Wire Dual Chamber Housing ​ RS485 MODBUS-RTU Communication Protocol/Four-Wire ​ Special Custom ​ Cable Inlet ​ M20*1.5 NPT 1/2 ​ Scene Display/Programmed ​ LCD Without Backlight ​ LCD With Backlight Range ​ (0-5)m ​ (0-10)m ​ (0 -20)m ​ (0 -30)m ​ (0 -70)m ​ Special Custom ​ FRLT-81S ​ Application: Liquid Measurement ​ Measuring Range: 0-10m ​ Antenna Type: Lens/PTFE ​ Mounting Thread: Thread G3.5 ​ Beam Angle: 3° ​ Response Time: <0.6s (Due To Parameter Setting) ​ Medium Temperature: (-40-120)°C ​ DK Value Of Medium: 1.5 ​ Process Pressure: (-0.1-2) MPa ​ Accuracy: <2mm ​ Signal Output: (4-20)mA HART ​ Working Frequency: (76 -81) GHz ​ Explosion Proof Grade: Ex d[ia Ga] IIC T6 Gb ​ Instrument Type Standard Explosion Proof ​ Housing/Protection Grade ​ Aluminum Alloy/IP68 ​ Aluminum Alloy Dual Chamber/IP67 ​ Special Terms ​ Antenna Type ​ G3.5 Lens/PTFE ​ Anti-Corrosive ​ Process Connection Thread G3.5 ​ Flange DN80 PN10 ​ Flange DN80 PN10 Universal Type ​ Flange DN100 PN10 ​ Flange DN100 PN10 Universal Type ​ Special Terms ​ Electronic Unit ​ 2 Wires (4-20) mA 24VDC/HART ​ 4 Wires (4 -20) mA 220V AC ​ Special terms ​ Cable Inlet ​ NPT1/2 M20*1.5 Material Type ​ Solid Special Terms ​

68179d65be22ee500d53ff54 Card 2

product image
Level Transmitter

Capacitance Level Transmitter can be used for conductive as well as non conductive liquids. It is offered with PTFE sleeve for better insulation & to withstand high temperature in conductive tanks the insulated probe acts as one electrode & the tank wall as another electrode, any change in liquid level the dielectric value will change thereby changing the capacitance value proportional to the liquid level. In the case of nonconductive tanks, a reference probe is provided as a ground electrode. Output is 4-20mA, 4 wire connections for isolated supply & 3 wires for non isolated supply. 2 wire loop powered output is also available. Tank empty (4mA) & Full (20mA) calibration is through easy field calibration button. Rigid probe is offered for tank depth up to 3 mt & Flexible probe up to 15mtr. Capacitance Level Transmitter is available with a different mounting arrangement to suit customer requirement. It is widely used for water, diesel, oil and chemical application. Highlights : Excellent Design Used For Sensing Level Of Liquids Longer Service Life Specification: Type: 2 Wire (Loop powered), 3 wire (Non isolated), 4 wire (Isolated) 4-20 mA Input: 24V Dc Permissible Load: 500Ω Measuring Rage: 200 mm to 3000 mm in Rigid Probe Upto 15000 mm in Flexile Probe Pressure Max.: 5kg / cm 2 Temperature: -25 to 100Deg C Enclosure: Die Cast aluminium, Weatherproof or Flameproof Resolution: 5mm Accuracy: +0.5 % Fs Mounting: Threaded -½" / 1" / 2" bspm or Npt Flange - 1" /2" Asa/Ansi/Jis/din Mounting: SS 304 or SS 316

68179d65be22ee500d53ff54 Card 2

product image
Level Transmitter

Hydrostatic liquid level transducers and transmitters with flush diaphragm is designed fora wide variety of level measurement applications. This pressure sensor is protected by the stainless steel (SS) housing. Featuring the flush diaphragm makes it suitable to measure viscous media or media with small particles, so as to have diverse measurement applications. The standard reference pressure is gauge (or relative) pressure realized through a vent tube in the cable. The reference pressure can also be absolute pressure on request. We offer wide measuring range from 0~1 to 0~200 meter water column (mH2O) with measuring accuracy of 0.5%fs. Output signal is current loop (4~20mA,standard) Features : Measuring Ranges: 1M, 2M, 3M, 5M, 6M, 8M, 10M, 12M 15M, Higher Length On Request Output Signal: 4-20mA Accuracy: 0.5%Fs Compensated Temperature Range: 0~70Deg C Construction: All Stainless Steel Housing, Rigid And Robust Environment Protection: Ip68

68179d65be22ee500d53ff54 Card 2

product image
Level Transmitter

Ultrasonic Level Sensor is a non-contact ultrasonic continuous level measurement product based on sound technology. Ultrasonic Level sensors offers an affordable solution for a variety of applications for Water, wastewater, petrochemical, chemical, food, and beverage. We offer Ultrasonic Level Transmitter at a pocket-friendly price. Specification: Our entry level cost effective product Fast setup, configuration, and commissioning Maximum range of 20mts 4-20mA output LCD display False echo tracing Direct installation of tanks, vessels, and reactors Perfect for diesel oil tank measurements Extended range of 0.25 to 15 meter (0.8ft to 49ft) Integral LCD display, keypad and integral 4-20 mA output Automatic compensation for different environment Approved for installations in hazardous areas (Ex) Simple to install and configure Direct installation of tanks, vessels, and reactors

68179d65be22ee500d53ff54 Card 2

product image
Level Transmitter

Float Level Transmitter Float Level Transmitters Are Ideal For Continuous Level Monitoring In Water, Diesel, Chemical And Oils For Accurate Level Measurement. The Output Is Not Affected By Liquid Type, Temperature, Pressure And Other Physical Parameters. The Transmitter Is Factory Calibrated And Is Ready To Use. Construction: Float Level Transmitter Consists Of Non Magnetic Sealed Stem Containing Series Of Reed Switches And Resistor, Float Carrying Magnet, Mounting Adaptor (Or Flange) And Enclosure Containing Electronics. Consider Our Float Level Transmitters For All Your Continuous Liquid level Monitoring Needs Like Water, Diesel, Lube Oils, Fuels, Chemicals And Petrochemical Liquids. Here Are Just Few Areas Where Transmitter Can Be Used. Utilities, Beverage Industry, Medical, Pharmaceuticals, Food Processing, Breweries, Chemical, Petrochemical, Refinery Specification: Overall Length: 300 mm to 5000mm Measuring Error: ±0.25 % or Span Output Temperature Coefficient: ±0.007% / oC Resolution: 5mm / 10mm Ambient Temperature: -40oC to 60oC Liquid Temp. Range: -40oC to 120oC Liquid Min. Density: 0.8 gm/cc Max. Pressure: 10 kg/cm2 Protection category: Weatherproof Ip66 to IS: 2147 (or) Flame Proof Gr. IIA & IIB to IS: 2148 Terminals: Max. 1.5mm2 Flexible Cable Entry: PG11 for weather Proof ¾" Et for Flameproof (Glands not supplied) Current Output: 2 wire, 4... 20 A 3 wire, 0-10 Vdc Process Connection: Threaded Flanged Tri-clamp Others Excitation Voltage: 10-36 V DC Loop Resistance: Max. 1200 Ohms

Phone Number

08045135424

Please keep 0 before dialling the number.

Email Address sales@filprosensors.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Magadi Main Road , Govindaraja Nagar Ward , Pete Channappa Industrial Estate

Bengaluru, India, 560079